From: Sara Turner (sturner@zoo.uvm.edu)
Date: Wed Jan 13 1999 - 09:38:00 EST


Dear Dr. McLaughlin,

I guess I wasn't very clear in my recent posting about using an HP 890C
Deskjet printer with System II software.  We have two PC's hooked up to our
HP 890C  printer through an automatic switchbox.    One computer is a Win
98 Pentium that we use for analysis and administrative kinds of work.  The
other computer is hooked up to the XL.  The XL's computer was set up by
Coulter to be bootable in both Win 95 or in DOS, but we MUST boot the
machine in DOS to use the System II software.  According to the Coulter
tech, the DOS part of the hard-drive is, in effect, "hidden" away from the
Win 95 part, because Win 95 is a real operating system which would take
over DOS if it could.  The System II software does not work in the
"pseudo-DOS" that comes with Win95.  I'm not sure why.  Anyway, we
occasionally use the XL's computer in Win 95 mode to ftp listmode files or
to do analysis with WinMidi, but we do most of our analysis on  the other
Win 98 PC using WinMidi,Verity WinList or ModFit.

Coulter does have software available, called EXPO, that can run the flow
and do analysis in Win 95 mode.   However,  I like System II better for
running the flow, and the Verity and WinMidi software for analysis.  You
can download WinMidi at http://facs.scripps.edu/software.html and the
Verity site is at http://www.vsh.com/.   Phoenix Flow Systems also sells
analysis software,  http://www.vsh.com/.

Sara



>Dear Dr. Turner,
>
>	Hello.  I am a graduate student at the University of Minnesota.  I
>am currently using the Epics XL to analyze maize endosperm nuclei.  I
>would like to setup the system 2.1 software on a Win95 system to analyze
>my listmode data on a machine away from the lab but haven't been able to
>install the software on any machine running windows 95- the video driver
>has been giving me problems and nothing is able to display.  The computer
>indicates that the problem is with the high resolution graphics that are
>handled just fine by the 486 machine in the lab with VDI/CGI and a
>1024X720 display.
>
>	Since you mentioned that you run the system II software on a Win95
>machine, I was hoping you could let me know the proper
>configuration/hardware requirements.  I am not interested in collecting
>data points from the flow on this machine.
>
>	Any advise you could offer would be helpful.
>
>	Thank you in advance,
>
>	John McLaughlin
>	University of Minnesota
>	Agronomy and Plant Genetics
>	mclau005@tc.umn.edu