Hi, the paper on detection of low levels of pgp in leukaemic blasts
is in Cytometry (15:64-72, 1994). More recent than I thought.
It's largely a mathematical treatment of the data using a
custom program for histogram subtraction to yeild more accurate
percent positives. I think you can get similar results using
mean, net fluorescence.

td

--
==============================================================================
 Thomas Delohery                        | Internet: t-delohery@ski.mskcc.org
 Manager, Flow Cytometry Core Facility  |    Phone: (212) 639-8729
 Memorial Sloan-Kettering Cancer Center |      Fax: (212) 794-4019
 1275 York Ave. Box 98                  |
 New York, NY    10021                  |
==============================================================================
 


Home Page Table of Contents Sponsors Web Sites
CD ROM Vol 2 was produced by staff at the Purdue University Cytometry Laboratories and distributed free of charge as an educational service to the cytometry community. If you have any comments please direct them to Dr. J. Paul Robinson, Professor & Director, PUCL, Purdue University, West Lafayette, IN 47907. Phone:(317) 494-0757; FAX (317) 494-0517; Web http://www.cyto.purdue.edu EMAIL robinson@flowcyt.cyto.purdue.edu